Sample Questions
1 BS 7671 relates to permanent and temporary installations for equipment on:
a marinas.
b ships.
c equipment on aircraft.
d railway traction equipment.
2 Which of the following is listed with the exclusions from the scope in the BS 7671:
a. Swimming pools
b. Saunas
c. Highway power supplies and street furniture
d. Suppliers works
3 Which one of the following is not a statutory regulation?
a Electricity at Work Regulations 1989 as amended
b The Supply of Machinery (Safety) Regulations 1992 as amended
c Requirements for Electrical Installations (BS 7671)
d Agricultural (Stationary Machinery) Regulations
4 The selection of the type of wiring and method of installation is not influenced by
a the nature of the location
b the load current
c the value of the prospective short-circuit current
d the nature of the structure supporting the wiring.
5 An area or temporary structure used for display, marketing or sales is defined as
a a booth
b a stand
c an exhibition
d a show
Click this Link to Download File:
Thread Discussion
City and Guilds 2382-10 17th Edition Past Exam Questions - Paper 3
Use the past paper to test your knowledge on the 17th Edition City and Guilds 2382-10, using this alongside the IET BS7671 is the best way to pass your exam. This paper is complete with the Answers.
Multiple Choice (Four Answers per question - one is correct)
Sample Questions
1 BS 7671 relates to permanent and temporary installations for equipment on:
a marinas.
b ships.
c equipment on aircraft.
d railway traction equipment.
2 Which of the following is listed with the exclusions from the scope in the BS 7671:
a. Swimming pools
b. Saunas
c. Highway power supplies and street furniture
d. Suppliers works
3 Which one of the following is not a statutory regulation?
a Electricity at Work Regulations 1989 as amended
b The Supply of Machinery (Safety) Regulations 1992 as amended
c Requirements for Electrical Installations (BS 7671)
d Agricultural (Stationary Machinery) Regulations
4 The selection of the type of wiring and method of installation is not influenced by
a the nature of the location
b the load current
c the value of the prospective short-circuit current
d the nature of the structure supporting the wiring.
5 An area or temporary structure used for display, marketing or sales is defined as
a a booth
b a stand
c an exhibition
d a show