can anyone help me i have a pace box and when i put power cable in error 20 comes up is there a fix for this


can anyone help me i have a pace box and when i put power cable in error 20 comes up is there a fix for this





heres a few . looks like its trying to lock on and update or get signal
Err1_ CRC fail across Primary Loader image.
Err2_ No longer used.
Err3_ Insufficient NVRAM
Err4_ Flash Fail or can't find platform object
Err5_ NVRAM not found
Tuning Sequence Related Errors
Er10_ Unable to Tune to Last frequency
Er11_ Unable to Tune to Home Frequency
Er12_ Unable to Tune to any of the last NIT defined frequencies
Er13_ Unable to scan for a frequency
Er14_ Unable to scan for a symbol rate
Er16_ Unable to tune to hardcoded frequency
Input Stream Errors
Er20_ Timeout on receiving NIT
Er21_ Timeout on receiving PAT
Er22_ Timeout on receiving PMT
Er23_ Timeout on receiving object data
Er24_ Timeout on receiving TDT
Er25_ Sync loss has occurred on the input stream


in this case the error chart above is wrong!!!!
since the elapsed time is insufficient for the nit timeout error to be correct..
This is likely a corrupted flash or 1 of the 2 atties is fooked.
solution - first reflow (may cure it but i doubt it)
second remove them and reprogramme with a working dump or find a donor box with another fault and swap the atties out - but be careful that the model number tallies exactly if you do this..
tbc
Bookmarks